Heavy Duty Anodized Aluminum Full Mortise Continuous Geared - designed mainly for new door applications that require extra clearance due to special frame, door or wall design.
Applied to conceal both leaves.
More clearance between the door and frame allows your door to open 180 degrees.
Available only in heavy duty (HD1) to support larger doors.
Available in 83", 95" and 120" lengths.
Fasteners are No. 12-24 x 11/16" #10 Head FHUC, Type C, threadforming, no tapping required.
Heavy duty models: 20 fasteners required for each leaf.
Wood screws available on request (specify on order).
Heavy duty hinge (HD1): 3" between bearing centers.
HD1 hinges conform to Grade 2-150, Grade 1-300, and Grade 1-600 cycle requirements per BHMA standard ANSI/BHMA A156.26-2006.
Tested and certified by Underwriters Laboratories Inc. (USA and Canada) to standard UL10B, UL10C and UBC 7.2 (positive pressure) for up to a 3-Hour (A-Label) fire listing for all 4 ft. 0 in. x 10 ft. 0 in.
and 8 ft. 0 in. x 10 ft. 0 in. door and frame assemblies. Fire listing certifications apply to all approved hollow metal and wood door assemblies in drywall or masonry construction.
Aluminum continuous hinge for use on swinging type fire doors of the hollow metal, tin-clad, sheet metal and steel covered composite type rated up to 3 hours, wood covered composite type rated up to and including 1-1/2 hours. Also wood core rated up to and including 20 minutes without hose stream.
All hinges meet criteria of UBC 7.2 for positive pressure.
Special FirePins are only required on 3-Hour (A-Label) assemblies.
Certain door and frame conditions may require an extra 1/32"-1/16" clearance. Excessive clearance on fire rated assemblies may violate the requirements for NFPA 80.
PemkoHinge products are guaranteed for the life of the opening against defects in material or workmanship wit hthe exception of AL, RS, standard duty and Grade 3 hinges, which carry a 10 year warranty.
Weight bearing (per BHMA standard ANSI/BHMA A156.26-2006) for heavy duty models: 83" and 85" = 27 bearings, door weight = 540 lbs.; 95" = 31 bearings, door weight = 620 lbs.; 120" = 39 bearings, door weight = 780 lbs.
Special hinge reinforcements are not required. Hollow metal door and frame manufacturers’ standard is acceptable. Removal of hinge reinforcements in the door and frame is not advised.
Width: 5/16” (7.9 mm) (between frame edge and door edge, square edge door applications).
Width: 3/8” (9.5 mm) (between frame edge and door edge, beveled edge door applications).
Cap Width: 25/32” (19.8 mm).
Height: 1-9/16” (39.7 mm) (to top cap/frame edge & door edge sides).
Height: 1-11/16” (42.9 mm) (to flange/frame edge & door edge sides).