Sargent 12-56-60-8806G-ETP-10BE RHR 8800 Series Fire Rated Rim Exit Device Retrofit Kit, Mortise LFIC, RHR, 48inSargent 12-56-60-8806G-ETP-10BE RHR KIT is a robust solution designed for environments requiring reliable safety and security. This fire-rated exit device from the 8800 Series features a motorized electric latch retraction (MELR), ensuring smooth operation while enhancing security. The storeroom exit trim operates via a key, allowing for controlled access, while the escutcheon with P lever adds both functionality and style. Crafted for standard width stiles on both wood and metal doors, this device meets ANSI/BHMA Grade 1 standards for strength and durability, making it ideal for high-traffic areas. The 12-56-60-8806G-ETP-10BE accommodates various door types, with a minimum door thickness of 1-3/4" and a stile width of 4-1/2". It is compatible with single and double door applications, including those with mullions. With an appealing dark oxidized bronze finish, the device not only provides a visual upgrade but also ensures long-lasting performance. It includes a 649 standard black nylon-coated strike and features hex key dogging for easy operation. The exit device is UL10C and UL305 listed, ensuring compliance with fire safety and panic exit requirements. Enhance your building's security with the Sargent 12-56-60-8806G-ETP-10BE RHR KIT, where safety meets sophistication.
KIT - Fire Rated, 8800 Series Rim Exit Device, M56A MELR Retrofit Kit, (Motorized Electric Latch Retraction), Storeroom Exit Trim (Key Operates Lever), Escutcheon with P Lever, Keyed Trim, Mortise LFIC (Large Format Interchangeable Core Housing Only, Less Core), 48in, Grade 1, RHR Right Hand Reverse, 613E/US10BE Dark Oxidized Bronze
Notice: The info below is not item specific.
The 80 series exit device is ideal for environments that require strong and durable security solutions. Made to last the lifetime of the building, this device easily exceeds ANSI/BHMA grade 1 requirements for cycle and strength and is available in rim, mortise, surface vertical and concealed vertical rod configurations. With a modular design, this device has been crafted to be maintenance-free and provide unsurpassed security for any facility. Plus, options are available for unique applications – including delayed egress, alarmed exit and electric latch retraction – making this the go-to product for your building.
Features:
- Designed for standard width stile applications on wood and metal doors
- Also available as an HC8800 or WS8800 for hurricane-resistant applications
- Single point rim latching device
- Single door & double door applications with mullions
- Quiet operation and solid security
- ANSI/BHMA A156.3 - Grade 1
- UL10C (Fire) and UL305 (Panic) Listed
Functions:
- 04: Night latch, key retracts latch #34 cylinder supplied. ANSI 03
- 06: Key unlocks trim, trim retracts latch/trim relocks when key is removed #41 cylinder supplied. ANSI 09
- 10: No outside operation (no cylinder). ANSI 01
- 10: No outside operation (no cylinder) ET control is used as pull only. ANSI 02
- 13: Key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 15: Passage only (no cylinder). ANSI 14
- 16: Key outside retracts latch; key inside unlocks/locks O/S trim, O/S #34 cylinder & I/S #44 cylinder supplied. ANSI 10
- 40: Freewheeling trim - no outside operation (no cylinder) dummy trim. ANSI 02
- 43: Freewheeling trim - key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 44: Freewheeling trim - key retracts latch, #34 cylinder supplied. ANSI 03
- 46: Freewheeling trim - Key unlocks trim, trim retracts latch/relocks when key is removed #41 cylinder supplied. ANSI 09
- 73: Electrified ET trim - fail safe power off, unlocks lever (no cylinder)
- 74: Electrified ET trim - fail secure power off, locks lever (no cylinder)
- 75: Electrified ET trim - fail safe power off, unlocks lever, key retracts latch, #34 cylinder supplied
- 76: Electrified ET trim - fail secure power off, locks lever, key retracts latch, #34 cylinder supplied
Specifications:
- Door Type: Metal doors
- Door Thickness: 1-3/4" (44mm) minimum thickness. For doors over 1-3/4" to 5" thick, specify thickness and order as 31-
- Stile: 4-1/2" (114mm) minimum stile width
- Rail sizes as determined by door width:
- E Rail for 24" to 32" door widths, no cutting required for 32" door
- F Rail for 33" to 36" door widths, no cutting required for 36" door
- J Rail for 37" to 42" door widths, no cutting required for 42" door
- G Rail for 43" to 48" door widths, no cutting required for 48" door
- Strike: 649 Standard black nylon coated
- Dogging Feature: Hex key dogging standard on non fired rated devices; specify 16- for cylinder dogging (#41 cylinder supplied)
- Electric Options:
- AL: Alarm
- PL: SARGuide photoluminescent coated
- 53: LX Latchbolt monitor
- 54: Outside lever monitoring
- 55: Request-to-exit signal - rail monitoring
- 56: ELR Remote latch retraction
- 58: Electric dogging
- 59: Electroguard – self contained delayed egress
- Mounting Fasteners: Supplied standard with wood and machine screws. Available with through-bolts and mortise (sex) nuts
- Latch Bolt: Stainless steel, 3/4" (19mm) throw
- Device Centerline from: 41" (1041 mm) for standard applications
- Center Case Dimensions: 8-3/8" (213mm) x 2-5/8" (67mm)
- Projection: Push bar neutral – 3" (76mm), push bar depressed – 2-1/8" (54mm)
Finishes:
- 03/605 - Bright brass, clear coated
- 04/606 - Satin brass, clear coated
- 09/611 - Bright bronze, clear coated
- 10/612 - Satin bronze, clear coated
- 10B/613 - Dark oxidized satin bronze, oil rubbed
- 10BE/613E - Dark oxidized satin bronze, equivalent
- 10BL/613L - Dark oxidized satin bronze clear coated
- 14/618 - Bright nickel plated, clear coated
- 15/619 - Satin nickel plated, clear coated
- 20D/624 - Dark statuary bronze lacquered
- 26/625 - Bright chrome plated
- 26D/626 - Satin chrome plated
- 32/629 - Bright stainless steel
- 32D/630 - Satin stainless steel
- BSP - Black suede powder coat
- WSP - White suede powder coat
Attributes
Alternate Codes: 12-56-60-8806G-ETP-10BE RHR, 1256608806GETP10BERHR
Category: Electrified Panic Devices, Panic Devices & Exit Alarms
Cylinder Type: Construction Core, Disposable Plastic Construction, Interchangeable , Removable Core
Door Application: Panic Devices
Door Thickness: 1-3/4"
Exit Device Part Type: Motorized Electric Latch Retraction Kit, UL Fire Label
Finish Code: 10BE, 613E
Finish Color: Dark Oxidized Satin Bronze
Handing: Right Handed Reverse
Lever Design: G, P
Series: 8800
Trim Option: Exit Trim