NGP 137SA (SET) 60" Anodized Aluminum Silicone Smoke-Rated Astragal delivers outstanding performance for commercial restroom partitions. Crafted from durable aluminum alloy 6063 with T5 temper and enhanced with a synthetic rubber polymer, Siloxane, this astragal ensures excellent flexibility and memory, maintaining its integrity even in extreme temperatures ranging from -100°F to 500°F. This product is flame resistant and moisture resistant, making it ideal for environments utilizing FM200 or Halon Fire Suppression Systems. The NGP 137SA is designed to meet rigorous safety standards, including IBC, NFPA 80, NFPA 105, and NFPA 252, ensuring the gap at the meeting edge between fire-labeled doors does not exceed 1/8". Included with your order are #6 x 3/4" stainless steel sheet metal screws, with slotted screw holes for easy adjustment during installation. The silicone material is gray, providing a sleek finish that complements the anodized aluminum. Designed to enhance both the functionality and safety of your restroom partitions, the NGP 137SA is a reliable choice for building professionals seeking quality hardware solutions. Order as a set to receive two pieces, ensuring comprehensive coverage for your installation needs.
60" Anodized Aluminum Silicone Smoke-Rated Astragal
Application: Excellent flexibility and memory
Color: Silicone is gray
Fasteners: #6 x 3/4" stainless steel sheet metal screws furnished
Finish: Anodized aluminum
Fire Rated: IBC, NFPA 80, NFPA105, and NFPA 252 require the gap at the meeting edge between fire labeled doors must not exceed 1/8"
Length: 60.0"
Material: Synthetic rubber polymer: Siloxane
Moisture Resistant: YES
Resistance: Excellent resistance to ozone, UV and aging
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature range -100°F to 500°F, remains flexible at extreme temperatures