NGP 950S 60" ADA Compliant Aluminum Bumper Threshold is a robust solution for ensuring seamless access in commercial spaces. Constructed from high-quality aluminum alloy 6063 with a T5 temper, this threshold measures 5 inches wide and 1/2 inch tall, making it an excellent choice for use with automatic door bottoms. The smooth top design not only enhances aesthetics but also facilitates easy passage for individuals with mobility challenges. Weighing only 0.50 lbs. per foot, this threshold features a typical wall thickness of 0.078 inches, providing durability without excessive bulk. Each unit comes furnished with #10 x 1-1/2" FH zinc-plated wood screws, while dark bronze options are available for DKB thresholds. The mill finish ensures long-lasting performance in demanding environments. Certified by UL for various fire door applications, the NGP 950S meets ADA standards and complies with ICC/ANSI A117.1, making it a sound investment for accessibility and safety. It has also been acoustically tested to ASTM standards, ensuring effective sound insulation. With its included silicone bumper seal, this threshold combines practicality with compliance, making it an essential addition to any restroom partition setup.
60" ADA Compliant Aluminum Bumper Threshold, 1/2" x 5"
Application: Excellent for use with automatic door bottoms
Dimensions: 5" wide x 1/2" tall
Fasteners: #10 x 1-1/2" FH zinc plated wood screws furnished. Dark bronze supplied with DKB thresholds
Finish: Mill finish
Length: 60.0"
Material: Aluminum alloy 6063, T5 temper
Standard-0: ADA COMPLIANT. Barrier Free Thresholds meet the requirements of the ADA Standard for Accessible Design and ICC/ANSI A117.1 Accessible and Usable Buildings and Facilities.
Standard-1: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Wall Thickness: Typical Wall Thickness: .078"
Weight: Weight: .50 lbs./ft.