NGP ANTI-LIG 5050C 48" Self-Adhesive Anti-Ligature Fire Smoke Seal is a specialized solution designed for environments such as psychiatric facilities and prisons. Its unique anti-ligature feature incorporates serrations every 8 inches, effectively breaking apart to prevent misuse for hanging or strangling. This seal maintains superior sealing properties against light, sound, air, and smoke, ensuring safety and comfort. Crafted from synthetic rubber polymer (Siloxane), it offers excellent flexibility and memory, remaining effective in extreme temperatures ranging from -100°F to 500°F. Its flame resistance and moisture resistance make it ideal for various applications, including areas using FM200 or Halon Fire Suppression Systems. The NGP ANTI-LIG 5050C is BHMA Certified to ANSI/BHMA A156.22 performance standards, ensuring high-quality performance for heat, cold, and air infiltration. With a long-term adhesive exposure range of -30°F to 250°F, it provides strong initial adhesion as well as enduring holding power, suitable for both interior and exterior installations. Available in a charcoal finish, this 1/2" wide x 1/4" tall seal comes in 48" rolls and is resistant to aging, UV radiation, and various chemicals, meeting the requirements of the RoHS directive for environmental safety.
Attributes
Application: Excellent flexibility and memory
BHMA: BHMA Certified to ANSI/BHMA A156.22 performance tests for heat, cold and air infiltration
Color: Charcoal
Dimensions: 1/2" wide x 1/4" tall
Fire Rated: Smoke and draft control - category "H", up to 3 hours hollow metal fire doors, up to 90 minutes wood fire doors
Length: 48.0"
Material: Synthetic rubber polymer: Siloxane
Moisture Resistant: YES
Resistance: Resistant to aging, weathering, UV radiation, water, detergent, alcohol and the influence of chemicals
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-5: NGP-EDGE® SEALING SYSTEM. Certified by UL to ANSI/UL10C Category ‘G’; required for Category B wood fire doors to meet positive pressure requirements complying with IBC, and NFPA 252. See individual products for maximum door size and ratings.
Standard-6: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: End use temperature range of adhesive, long term exposure -30°F up to 250°F