NGP 159MA 60" Anodized Aluminum Magnetic Seal provides a reliable solution for sealing restroom partitions, enhancing both functionality and aesthetics. Crafted from durable aluminum alloy 6063 in T5 temper, this magnetic seal ensures longevity and resilience in commercial environments. The magnet is encased in gray vinyl, offering a sleek appearance while providing effective sealing capabilities. Designed with an environmentally friendly Bio-based plasticizer, the thermoplastic polymer (PVC) used in this product is not only economical but also flame and moisture resistant, making it suitable for a variety of restroom applications. It can withstand temperature ranges from 0°F to 140°F, ensuring performance in diverse conditions. Installation is made easy with slotted screw holes for adjustment, and it comes furnished with #6 x 3/4" stainless steel SMS fasteners. The maximum length extends to 144", allowing for customization based on specific needs. Additionally, the NGP 159MA meets rigorous safety standards, being certified by UL for fire-rated applications, including hollow metal fire doors rated up to 3 hours and wood fire doors rated up to 90 minutes. This product is a practical choice for building professionals looking to enhance the durability and safety of their restroom partitions.
60" Anodized Aluminum Magnetic Seal
Color: Magnet encased in gray vinyl
Fasteners: #6 x 3/4" stainless steel SMS furnished
Finish: Anodized aluminum
Fire Rated: Flame resistant
Length: 60.0"
Material: Thermoplastic polymer: Polyvinyl Chloride (PVC) formulated with an environmentally friendly Bio-based plasticizer
Maximum Length: Maximum length 144"
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Temperature Range: Temperature range 0°F to 140°F