NGP 312V X 131N 48" Acoustical Door Shoe provides a reliable solution for enhancing the performance of commercial restroom partitions. Crafted from durable aluminum alloy 6063 with T5 temper and thermoplastic polymer PVC, this door shoe is formulated with an environmentally friendly bio-based plasticizer, ensuring both strength and sustainability. This product is designed to withstand a temperature range of 0°F to 140°F, making it suitable for various environments. Its flame and moisture-resistant properties enhance safety and durability, while the black vinyl provides a sleek, professional appearance that complements any restroom interior. The NGP 312V X 131N features slotted screw holes for easy adjustment and comes with #6 x 3/4" stainless steel SMS fasteners, promoting straightforward installation. Additionally, it is certified by UL for use on hollow metal fire doors rated up to 3 hours and wood fire doors rated up to 90 minutes, ensuring compliance with NFPA 80 and other safety standards. Acoustically tested to ASTM E90, this door shoe effectively reduces sound transmission, making it an excellent choice for spaces requiring noise control. With its robust construction and impressive specifications, the NGP 312V X 131N is an economical choice for enhancing restroom partition hardware.
48" Acoustical Door Shoe
Color: Vinyl is black
Fasteners: #6 x 3/4" stainless steel SMS furnished
Fire Rated: Flame resistant
Length: 48.0"
Material: Mill aluminum
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature range 0°F to 140°F