NGP 913DKB 84" DKB-finish Aluminum Saddle Threshold combines functionality with a sleek design, making it an essential addition to any commercial restroom. Crafted from durable aluminum alloy 6063 in T5 temper, this threshold measures 9" wide and 1/4" tall, ensuring a robust barrier while maintaining a low profile for easy access. The fluted top enhances both aesthetics and grip, providing a secure footing. This threshold is BHMA certified to ANSI/BHMA A156.21, capable of withstanding a 1,000 lb. load test, making it ideal for high-traffic areas. Weighing just 1.41 lbs. per foot, it is lightweight yet sturdy, accommodating typical wall thicknesses of .125". The elegant dark bronze finish not only adds a touch of sophistication but also resists wear and tarnish. Included with the threshold are #10 x 1-1/2" FH zinc-plated wood screws, facilitating a straightforward installation process. The NGP 913DKB also meets ADA compliance standards, ensuring barrier-free access for all users. With its reliable construction and thoughtful design, this threshold is a smart choice for enhancing the functionality and appearance of restroom partitions.
84" DKB-finish Aluminum Saddle Threshold, 1/4" x 9"
BHMA: BHMA certified to ANSI/BHMA A156.21 1,000 lb. load test
Dimensions: 9" wide x 1/4" tall
Fasteners: #10 x 1-1/2" FH zinc plated wood screws included
Finish: Dark bronze finish
Length: 84.0"
Material: Aluminum alloy 6063, T5 temper
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 96" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Standard-0: ADA COMPLIANT. Barrier Free Thresholds meet the requirements of the ADA Standard for Accessible Design and ICC/ANSI A117.1 Accessible and Usable Buildings and Facilities.
Standard-1: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-3: ANSI/BHMA CERTIFIED. Certified thresholds comply with American National Standard for Thresholds ANSI/BHMA A156.21 1,000 lb. load test and are listed in the BHMA Certified Products Directory.
Wall Thickness: Typical wall thickness .125"
Weight: Weight: 1.41 lbs./ft.