1. Home
  2. Shopping Cart
Sargent 12-56-LC-8706G-ETP-32D RHR 48X84 8700 Series SVR Fire Rated Exit Device Retrofit Kit, Grade 1, Stainless Steel
Images may not represent actual product and finish

Sargent 12-56-LC-8706G-ETP-32D RHR 48X84 8700 Series SVR Fire Rated Exit Device Retrofit Kit, Grade 1, Stainless Steel

Your Price: $4,055.63
Retail Price:$6,489.0000
Your Savings:$2,433.37(37%)
Sargent 8700 Series Exit Device: Fire-rated, motorized latch retraction, durable stainless steel for enhanced security and easy access.
Part Number : SAR_1256LC8706GETP32DRHR48X84
Availability: 2 In Stock
Sargent 12-56-LC-8706G-ETP-32D RHR 48X84 8700 Series SVR Fire Rated Exit Device Retrofit Kit, Grade 1, Stainless Steel

Sargent 12-56-LC-8706G-ETP-32D RHR 48X84 KIT is a robust solution designed for high-security environments that demand exceptional durability and functionality. This fire-rated exit device from the 8700 Series features surface vertical rod (SVR) construction, ensuring reliable performance under pressure. The integrated motorized electric latch retraction (MELR) enhances security while allowing for seamless access, making it ideal for storerooms and other critical areas. Crafted from Grade 1, satin stainless steel, this exit device meets ANSI/BHMA standards for cycle and strength, ensuring it withstands the rigors of daily use. Its two-point latching system secures both the top and bottom of the door, providing added peace of mind. The trim operates with a key, allowing for controlled access while the less mortise cylinder design simplifies installation. Designed for wood or metal doors with a minimum thickness of 1-3/4 inches, the Sargent 12-56-LC-8706G-ETP-32D accommodates a range of door widths, from 24 inches to 48 inches, without the need for cutting. With multiple electric options available, including alarm features and remote latch retraction, this exit device is versatile enough to meet unique security needs while adhering to fire safety regulations.

KIT - Fire Rated, 8700 Series SVR (Surface Vertical Rod) Exit Device, M56A MELR Retrofit Kit, (Motorized Electric Latch Retraction), Storeroom Exit Trim (Key Operates Lever), Escutcheon with P Lever, Less Mortise Cylinder (1-1/8in), RHR Right Hand Reverse, 48in x 84in, Grade 1, 630/US32D Stainless Steel

Notice: The info below is not item specific.

The 80 series exit device is ideal for environments that require strong and durable security solutions. Made to last the lifetime of the building, this device easily exceeds ANSI/BHMA grade 1 requirements for cycle and strength and is available in rim, mortise, surface vertical and concealed vertical rod configurations. With a modular design, this device has been crafted to be maintenance-free and provide unsurpassed security for any facility. Plus, options are available for unique applications – including delayed egress, alarmed exit and electric latch retraction – making this the go-to product for your building.

Features:

  • Two point latching (top & bottom with adjustability through center case)
  • Standard bottom latch compatible with latch track thresholds (by others)
  • Single and double door applications
  • ANSI/BHMA A156.3 - grade 1
  • UL10C (Fire) and UL305 (panic) Listed
  • Also available as HC8700 for hurricane-resistant applications
  • Also available as FM8700, use with StormPro series doors, frames and hinges is required when used as a certified tornado solution.
  • Rods are 1/2" (13mm) brass, bronze or stainless steel

Functions:

  • 06: Key unlocks trim, trim retracts latch/trim relocks when key is removed #41 cylinder supplied. ANSI 09
  • 10: No outside operation (no Cylinder). ANSI 01
  • 10: No outside operation (no Cylinder) ET control is used as pull only. ANSI 02
  • 13: Key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
  • 15: Passage only (no cylinder). ANSI 14
  • 40: Freewheeling trim - no outside operation (no cylinder) dummy trim. ANSI 02
  • 43: Freewheeling trim - key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
  • 46: Freewheeling trim - Key unlocks trim, trim retracts latch/relocks when key is removed #41 cylinder supplied. ANSI 09
  • 73: Electrified ET trim - fail safe power off, unlocks lever (no cylinder)
  • 74: Electrified ET trim - fail secure power off, locks lever (no cylinder)

Specifications:

  • Door Type: Wood or metal doors
  • Door Thickness: 1-3/4" (44mm) minimum thickness. For doors over 1-3/4" to 5" thick, specify thickness and order as 31-
  • Stile: 4-1/2" (114mm) minimum stile width with trim and 3-1/2" (44mm) minimum stile without trim
  • Rail sizes as determined by door width:
    • E Rail for 24" to 32" door widths, no cutting required for 32" door
    • F Rail for 33" to 36" door widths, no cutting required for 36" door
    • J Rail for 37" to 42" door widths, no cutting required for 42" door
    • G Rail for 43" to 48" door widths, no cutting required for 48" door
  • Strike: 646 Top strike (panic and fire rated), 624 bottom strike; 655 fire rated bottom strike
  • Dogging Feature: Hex key dogging standard on non fired rated devices; specify 16- for cylinder dogging (#41 cylinder supplied)
  • Electric Options:
    • AL: Alarm
    • PL: SARGuide photoluminescent coated
    • 53: LX Latchbolt monitor
    • 54: Outside lever monitoring
    • 55: Request-to-exit signal - rail monitoring
    • 56: ELR Remote latch retraction
    • 58: Electric dogging
    • 59: Electroguard – self contained delayed egress
  • Mounting Fasteners: Supplied standard with wood and machine screws. Available with through-bolts and mortise (sex) nuts
  • Top & Bottom Bolt: Brass, stainless steel
  • Device Centerline from: 41" (1041 mm) for standard applications; 38"(965mm) for elementary schools
  • Door/Opening Height: Must be specified - 120" (3048mm) max door opening - non-fire rated doors. 96" (2438mm) max door opening - fire rated doors
  • Center Case Dimensions: 8-3/8" (213mm) x 2-5/8" (67mm)
  • Projection: Push bar neutral – 3" (76mm), push bar depressed – 2-1/8" (54mm)

Finishes:

  • 03/605 - Bright brass, clear coated
  • 04/606 - Satin brass, clear coated
  • 09/611 - Bright bronze, clear coated
  • 10/612 - Satin bronze, clear coated
  • 10B/613 - Dark oxidized satin bronze, oil rubbed
  • 10BE/613E - Dark oxidized satin bronze, equivalent
  • 10BL/613L - Dark oxidized satin bronze clear coated
  • 14/618 - Bright nickel plated, clear coated
  • 15/619 - Satin nickel plated, clear coated
  • 20D/624 - Dark statuary bronze lacquered
  • 26/625 - Bright chrome plated
  • 26D/626 - Satin chrome plated
  • 32/629 - Bright stainless steel
  • 32D/630 - Satin stainless steel
  • BSP - Black suede powder coat
  • WSP - White suede powder coat

Attributes

Alternate Codes: 12-56-LC-8706G-ETP-32D RHR 48X84, 1256LC8706GETP32DRHR48X84

Category: Electrified Panic Devices, Panic Devices & Exit Alarms

Cylinder Type: Less Cylinder

Door Application: Panic Devices & Exit Alarms

Exit Device Part Type: Motorized Electric Latch Retraction Kit, UL Fire Label

Finish Code: 630

Finish Color: Satin Stainless Steel

Handing: Right Handed Reverse

Series: 8700

Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 84" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.

Recently Viewed Items