1. Home
  2. Shopping Cart
Altronix STRIKEIT1 Power Supply
Images may not represent actual product and finish

Altronix STRIKEIT1 Power Supply

Your Price: $536.27
Retail Price:$746.77
Your Savings:$210.50(28%)
Pabic Device Power Controller, 115VAC 60Hz at 6.3A Input, Multiple Output Power Options, Grey Enclosure
Part Number : ALT_STRIKEIT1
Availability: 26 In Stock
Altronix STRIKEIT1 Power Supply

STRIKEIT1 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current surge panic hardware locking devices demand. Each lock output has an adjustable relock delay timer. It will control a pair of doors simultaneously or independently control two individual doors. It has a follower relay for each output to trigger external relays, ADA push plate switches, etc. Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day. In addition, two un-switched auxiliary voltage outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc. A configurable FACP interface will either provide power or remove power to the lock outputs when activated. LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision. Intelligent logic provides protection against accidental shorting of lock outputs.
  • Input:
  • Input 115VAC 60Hz, 6.3 amp.
  • Two (2) NO trigger inputs.
  • Input fuse rating: 6.3 amp.
  • Outputs:
  • Power options:
  • Two (2) 20VDC to 26.4VDC individually controlled lock outputs for applications with battery back-up. 24VDC for applications without battery back-up (US applications only). Current rating 15 amp for 300ms, 0.75 amp continuous supply current.
  • 5V holding voltage with 20VDC to 26.4VDC initial 100ms pulse. Maximum total 5V holding current of both outputs is 0.74 amp.
  • One (1) 20VDC to 26.4VDC for applications with battery back-up, 24VDC for applications in US not requiring battery back-up. Auxiliary output rated @ 0.75 amp continuous supply current (Not affected by FACP trigger).
  • One (1) 12VDC filtered regulated auxiliary output rated @ 0.75 amp in alarm, 0.5 amp stand-by current (Not affected by FACP trigger).
  • Two (2) follower form "A" SPST relay outputs rated @ 0.6 amp/28VDC. Relays energize while input is closed.
  • Two (2) delayed follower Normally Open relay outputs rated @ 0.6 amp/28VDC. Delay time is selectable 0.5 seconds or 1 second. Energized duration is 1 second.
  • Trouble relay output indicating low DC output voltage.
  • Battery Backup:
  • Battery leads included.
  • Battery fuse rating: 25A/32V.
  • Maximum charge current 650mA.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.
  • Visual Indicators:
  • Green AC Power LED indicates 115VAC present.
  • Red trigger input LEDs indicate panic device status/trouble (activated, short or open circuit).
  • Green Fire Alarm Interface (FAI) LED indicates FACP disconnect is activated.
  • Red Battery LED indicates low battery during AC failure and manual test.
  • Green AC LED indicates loss of AC trouble (not active during manual test sequence).
  • Fire Alarm Disconnect:
  • Normally Closed FACP trigger input.
  • Programmable Fire Alarm Disconnect options:
  • Removes power to outputs and disables delayed follower relays.
  • Connects power to lock outputs and enables delayed follower relays.
  • Additional Features:
  • Manual testing to allow to tests battery conditions.
  • Adjustable panic release from 1 sec. to 30 secs.
  • Note: Follower and Delay relay turns off when the potentiometer selected time elapses after release of the input trigger.
  • Cam lock included.
  • Electrical:
  • Operating temperature: 0° C to 49° C ambient.
  • BTU/Hr.: 196.5 BTU/Hr.
  • System AC input VA requirement: 218.5VA.
  • Mechanical:
  • Enclosure Dimensions (H x W x D approx.): 13.5" x 13" x 3.25" (342.9mm x 330.2mm x 82.55mm)
  • Enclosure accommodates up to two (2) 12VDC/7AH batteries.
  • Product weight (approx.): 6.25 lbs. (2.83 kg).
  • Shipping weight (approx.): 7.15 lbs. (3.24 kg).

Features

  • Outputs:
  • Input:
  • Battery Backup:
  • Input 115VAC 60Hz, 6.3 amp.
  • Power options:
  • Green AC LED indicates loss of AC trouble (not active during manual test sequence).
  • Enclosure accommodates up to two (2) 12VDC/7AH batteries.
  • Product weight (approx.): 6.25 lbs. (2.83 kg).
  • Green AC Power LED indicates 115VAC present.
  • Enclosure Dimensions (H x W x D approx.): 13.5" x 13" x 3.25" (342.9mm x 330.2mm x 82.55mm)
  • Additional Features:
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.
  • Red trigger input LEDs indicate panic device status/trouble (activated, short or open circuit).
  • Two (2) delayed follower Normally Open relay outputs rated @ 0.6 amp/28VDC. Delay time is selectable 0.5 seconds or 1 second. Energized duration is 1 second.
  • Visual Indicators:
  • One (1) 12VDC filtered regulated auxiliary output rated @ 0.75 amp in alarm, 0.5 amp stand-by current (Not affected by FACP trigger).
  • BTU/Hr.: 196.5 BTU/Hr.
  • Normally Closed FACP trigger input.
  • Electrical:
  • Mechanical:
  • Removes power to outputs and disables delayed follower relays.
  • Two (2) follower form "A" SPST relay outputs rated @ 0.6 amp/28VDC. Relays energize while input is closed.
  • Fire Alarm Disconnect:
  • Input fuse rating: 6.3 amp.
  • Green Fire Alarm Interface (FAI) LED indicates FACP disconnect is activated.
  • Shipping weight (approx.): 7.15 lbs. (3.24 kg).
  • Two (2) 20VDC to 26.4VDC individually controlled lock outputs for applications with battery back-up. 24VDC for applications without battery back-up (US applications only). Current rating 15 amp for 300ms, 0.75 amp continuous supply current.
  • Adjustable panic release from 1 sec. to 30 secs.
  • Note: Follower and Delay relay turns off when the potentiometer selected time elapses after release of the input trigger.
  • Manual testing to allow to tests battery conditions.
  • One (1) 20VDC to 26.4VDC for applications with battery back-up, 24VDC for applications in US not requiring battery back-up. Auxiliary output rated @ 0.75 amp continuous supply current (Not affected by FACP trigger).
  • 5V holding voltage with 20VDC to 26.4VDC initial 100ms pulse. Maximum total 5V holding current of both outputs is 0.74 amp.
  • Battery leads included.
  • Automatic switch over to stand-by battery when AC fails.
  • System AC input VA requirement: 218.5VA.
  • Maximum charge current 650mA.
  • Two (2) NO trigger inputs.
  • Trouble relay output indicating low DC output voltage.
  • Battery fuse rating: 25A/32V.
  • Programmable Fire Alarm Disconnect options:
  • Connects power to lock outputs and enables delayed follower relays.
  • Operating temperature: 0° C to 49° C ambient.
  • Red Battery LED indicates low battery during AC failure and manual test.
  • Cam lock included.
  • Built-in charger for sealed lead acid or gel type batteries.

Attributes

Manufacturer surcharge: $ 0.0

Access Type: Power Supply

Alternate Codes: 140447, PS873-2, PS8732, STRIKEIT1

Category: Access Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies

Commercial Residential: Commercial

Installation: Commercial

Pack Qty: 1

Purpose: General

Series: Altronix Power Supplies

Ship Weight: 13.6 lbs.

Subtype: Power Supply

Type: Wire-In Transformer

Unit of Measure: Each

Voltage/ Amp Rating: 24V DC