NGP 137NA (SET) 60" Anodized Aluminum Neoprene Smoke-Rated Astragal offers a robust solution for enhanced fire safety and moisture resistance in commercial buildings. Constructed from Aluminum Alloy 6063 with a T5 temper, this astragal is designed to withstand a wide temperature range of -81°F to 275°F, ensuring durability in various environments. The synthetic EPDM rubber embedded in a polypropylene thermoplastic matrix provides excellent abrasion resistance, tensile strength, and memory, making it a reliable choice for high-traffic areas. Certified by UL, this product complies with important fire safety standards, including IBC, NFPA 80, NFPA 105, and NFPA 252. It is crucial to note that while this fire-rated astragal enhances safety, it should not replace any required astragal on the door itself to maintain its fire label. The NGP 137NA includes slotted screw holes for easy adjustments and comes with #6 x 3/4" stainless steel screws for installation. Available in a sleek black anodized aluminum finish, this astragal is not only functional but also aesthetically pleasing. Order as a set to receive two pieces, ensuring you have everything needed for a complete installation.
60" Anodized Aluminum Neoprene Smoke-Rated Astragal
Color: Color is Black
Fasteners: #6 x 3/4" Stainless Steel SMS Furnished
Finish: Anodized Aluminum
Fire Rated: IBC, NFPA 80, NFPA105, and NFPA 252 Require the Gap at the Meeting Edge Between Fire Labeled Doors Must Not Exceed 1/8"
Length: 60.0"
Material: Aluminum Alloy 6063, T5 Temper
Moisture Resistant: YES
Resistance: Good Resistance to Ozone, Sunlight and Aging
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature Range -81°F to 275°F