Net 30 terms available
NGP 312V 60" Mill Aluminum Finned Vinyl Door Shoe is a robust solution designed to enhance the functionality of your commercial restroom partitions. Constructed from high-grade aluminum alloy 6063 with a T5 temper, this door shoe promises durability and longevity. The thermoplastic polymer, made of environmentally friendly Polyvinyl Chloride (PVC), adds to its resilience, ensuring it remains flame and moisture resistant. With a temperature range of 0°F to 140°F, the NGP 312V is engineered to withstand various environmental conditions, making it suitable for diverse applications. Its black vinyl finish not only provides a sleek appearance but also helps to minimize wear and tear. The product comes with #6 x 3/4" stainless steel screws, allowing for easy installation, while slotted screw holes enable precise adjustments. Certified by UL, this door shoe complies with numerous fire safety standards, including those for hollow metal and wood fire doors. Additionally, it has passed rigorous tests for air infiltration and sound insulation, ensuring it meets the demanding needs of commercial spaces. Choose the NGP 312V for a reliable, efficient, and stylish door shoe that enhances both safety and aesthetics in your restroom partitions.
60" Mill Aluminum Finned Vinyl Door Shoe
Color: Vinyl is black
Fasteners: #6 x 3/4" stainless steel SMS furnished
Fire Rated: Flame resistant
Length: 60.0"
Material: Mill aluminum
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature range 0°F to 140°F