Net 30 terms available
NGP 312VDKB X 131N 36" DKB-finish Acoustical Door Shoe offers a reliable solution for enhancing the performance of commercial restroom partitions. Crafted from high-quality aluminum alloy 6063 with a T5 temper, this door shoe is designed to withstand various environmental challenges. Its thermoplastic polymer, made from polyvinyl chloride, features an environmentally friendly bio-based plasticizer, ensuring both durability and sustainability. This door shoe is flame and moisture resistant, making it an economical choice for high-traffic areas. With a temperature range of 0°F to 140°F, it remains functional in diverse climates. The slotted screw holes allow for easy adjustments during installation, while the included #6 x 3/4" stainless steel SMS fasteners ensure a secure fit. The black vinyl material beautifully contrasts with the dark bronze finish, providing an attractive appearance that complements any restroom design. NGP's door shoe is not only acoustically tested to ASTM standards but is also certified for smoke and draft control, making it ideal for fire-rated applications. Rely on the NGP 312VDKB X 131N for a blend of performance, aesthetics, and compliance in your commercial restroom projects.
36" DKB-finish Acoustical Door Shoe
Color: Vinyl is black
Fasteners: #6 x 3/4" stainless steel SMS furnished
Finish: Dark bronze finish
Fire Rated: Flame resistant
Length: 36.0"
Material: Aluminum alloy 6063, T5 temper Thermoplastic polymer: Polyvinyl Chloride formulated with an environmentally friendly Bio-based plasticizer
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature range 0°F to 140°F