NGP 700N 84" Mill Aluminum Neoprene Perimeter Seal provides a robust solution for sealing your commercial restroom partitions. Crafted from high-quality Aluminum Alloy 6063 with T5 temper, this seal combines durability with performance, ensuring long-lasting use in demanding environments. Its synthetic EPDM rubber, encased in a polypropylene thermoplastic matrix, offers excellent abrasion resistance, tensile strength, and memory, making it highly effective in maintaining an airtight barrier. Designed for versatility, the NGP 700N is flame-resistant and moisture-resistant, operating efficiently within a temperature range of -81°F to 275°F. It boasts impressive resistance to ozone, sunlight, and aging, contributing to its longevity. The product is BHMA certified to ANSI/BHMA A156.22 performance tests for both heat and cold, ensuring compliance with industry standards. Installation is straightforward, with slotted holes for adjustment and self-drilling #8 (Tek Type) screws included. This perimeter seal allows for closer mounting without compromising the seal integrity and accommodates rim exit device strikes without the need for notching. The head section remains undrilled, providing additional flexibility during installation. Enhance the performance and safety of your restroom partitions with the reliable and efficient NGP 700N Perimeter Seal.
Attributes
BHMA: BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat and Cold
Color: Color is Black
Fasteners: Self Drilling #8 (Tek Type) Screws Furnished
Fire Rated: Flame-Resistant
Length: 84.0"
Material: Mill Aluminum
Moisture Resistant: YES
Resistance: Good Resistance to Ozone, Sunlight and Aging
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 96" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-5: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: Temperature Range -81°F to 275°F