NGP 890N 84" Aluminum NGP-TPV Bumper Seal Threshold, 3/4" x 5" combines functionality and durability for your commercial restroom needs. Constructed from high-quality aluminum alloy 6063 in T5 temper, this threshold measures 5 inches wide and 3/4 inch tall, making it an ideal choice for ensuring a seamless transition between spaces. Its typical wall thickness of .125 inches provides the strength needed for long-lasting performance. Weighing just .82 lbs. per foot, the NGP 890N is both lightweight and robust. It comes with #10 x 1-1/2" FH zinc-plated wood screws for easy installation, ensuring a secure fit. The mill finish offers a sleek appearance, while the NGP-TPV design is available in black, allowing for aesthetic versatility across various environments. This product is certified by UL for fire safety standards, making it suitable for use with hollow metal fire doors rated up to 3 hours and wood fire doors rated up to 90 minutes. Additionally, it has been air infiltration tested to ASTM E283, ensuring optimal performance against external elements. The NGP 890N is a reliable choice for building professionals seeking quality restroom partition hardware.
84" Aluminum NGP-TPV Bumper Seal Threshold, 3/4" x 5"
Color: NGP-TPV is black
Dimensions: 5" wide x 3/4" tall
Fasteners: #10 x 1-1/2" FH zinc plated wood screws furnished. Dark bronze supplied with DKB thresholds
Finish: Mill finish
Length: 84.0"
Material: Aluminum alloy 6063, T5 temper
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 96" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: ANSI/BHMA CERTIFIED. Certified thresholds comply with American National Standard for Thresholds ANSI/BHMA A156.21 1,000 lb. load test and are listed in the BHMA Certified Products Directory.
Standard-3: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Wall Thickness: Typical Wall Thickness: .125"
Weight: Weight: .82 lbs./ft.