NGP 9700A 36" Anodized Aluminum Silicone Perimeter Seal offers exceptional protection and flexibility for commercial applications. Constructed from durable aluminum alloy 6063 with T5 temper, this perimeter seal is designed to withstand extreme conditions with a temperature range of -100°F to 500°F, retaining its flexibility even at high temperatures. The synthetic rubber polymer, Siloxane, ensures excellent resistance to moisture, ozone, UV exposure, and aging, making it ideal for long-lasting performance. This seal is flame-resistant and recommended for areas utilizing FM200 or Halon Fire Suppression Systems, ensuring safety and compliance. It is BHMA Certified to ANSI/BHMA A156.22, meeting rigorous performance tests for heat, cold, air infiltration, and smoke infiltration. The design includes slotted holes for easy adjustment during installation and allows for mounting of rim exit device strikes without the need for notching the gasketing. Included self-drilling #8 (Tek type) screws facilitate straightforward installation. The sleek black silicone and anodized aluminum finish enhance aesthetic appeal while providing robust functionality. The NGP 9700A perimeter seal is the ideal choice for building professionals seeking reliability and performance in restroom partition hardware.
Attributes
Application: Excellent flexibility and memory
BHMA: BHMA Certified to ANSI/BHMA A156.22 performance tests for heat, cold, air infiltration and smoke infiltration
Color: Silicone is black
Fasteners: Self drilling #8 (Tek type) screws furnished
Finish: Anodized aluminum
Fire Rated: Recommended for areas using FM200 or Halon Fire Suppression Systems
Length: 36.0"
Material: Synthetic rubber polymer: Siloxane
Moisture Resistant: YES
Resistance: Excellent resistance to ozone, UV and aging
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-5: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: Temperature range -100°F to 500°F, remains flexible at extreme temperatures