NGP ANTI-LIG 5050C 72" Self-Adhesive Anti-Ligature Fire Smoke Seal is engineered for environments requiring enhanced safety and security, such as psychiatric facilities and prisons. Its innovative anti-ligature design features serrations every 8 inches, effectively preventing the material from being used for hanging or strangulation. This seal provides exceptional sealing properties for light, sound, air, and smoke, matching the performance of the original 5050 model. Crafted from a synthetic rubber polymer, Siloxane, it boasts excellent flexibility and memory, ensuring a reliable fit even in extreme temperatures ranging from -100°F to 500°F. The self-adhesive backing allows for easy installation, offering high initial adhesion and long-term holding power in both interior and exterior settings. Certified to ANSI/BHMA A156.22 performance standards, the seal is flame resistant, moisture resistant, and provides robust resistance to aging, UV radiation, and chemicals. With a width of 1/2" and height of 1/4", this seal is available in 72" lengths and is suitable for use with FM200 or Halon Fire Suppression Systems. Additionally, it meets the requirements of the RoHS directive, making it a responsible choice for modern facilities.
Attributes
Application: Excellent flexibility and memory
BHMA: BHMA Certified to ANSI/BHMA A156.22 performance tests for heat, cold and air infiltration
Color: Charcoal
Dimensions: 1/2" wide x 1/4" tall
Fire Rated: Smoke and draft control - category "H", up to 3 hours hollow metal fire doors, up to 90 minutes wood fire doors
Length: 72.0"
Material: Synthetic rubber polymer: Siloxane
Moisture Resistant: YES
Resistance: Resistant to aging, weathering, UV radiation, water, detergent, alcohol and the influence of chemicals
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 96" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-5: NGP-EDGE® SEALING SYSTEM. Certified by UL to ANSI/UL10C Category ‘G’; required for Category B wood fire doors to meet positive pressure requirements complying with IBC, and NFPA 252. See individual products for maximum door size and ratings.
Standard-6: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: End use temperature range of adhesive, long term exposure -30°F up to 250°F