NGP GAP90-ME 72" Meeting Edge and Door Perimeter Gap Solution provides an effective UL Certified solution for fire doors with excessive clearance, accommodating gaps up to 3/8". This product is application certified for both hollow metal and wood fire-rated doors, ensuring compliance for doors rated up to 90 minutes. Designed to be non-handed, the GAP90-ME can be installed without removing the door from its hinges, making it a convenient choice for building professionals. It is compatible with both surface and concealed vertical rod exit devices, as well as manual or automatic flush bolts. The formed metal edge is crafted from durable 20-gauge steel, embossed with the UL mark for assurance of quality. Field-modification capabilities allow for a customized fit to varying width gaps along the door's height, ensuring a precise installation. The product is available in sizes of 84" and 96", with a primer gray powder coat finish that enhances its aesthetic appeal while offering protection. Each hardware pack includes necessary components such as #10 FHPH SS TEK and SMS screws, as well as GapGuard™ Fire Caulk to ensure a comprehensive installation. The GAP90-ME is certified for use in both the US and Canada, meeting rigorous safety standards for fire-rated applications.
72" Meeting Edge and Perimeter Gap Solution – Wood Hollow Metal
Application: Can be Field-modified to Match-Fit Varying Width Gap Along Height of the Door (see installation instructions)
Certifications: Certified for use in US and Canada
Finish: Finish: Primer Gray, Powder Coat
Fire Rated: Hardware Pack: #10 x 3/4" FHPH SS TEK, #10 x 2-1/2" FHPH SS SMS, GapGuard™ Fire Caulk (see Installation Instructions)
Gauge: Product consists of: Formed Metal Edge, 20-Gauge Steel, Embossed with UL Mark
Handing: Non-Handed
Length: 72.0"
Patented: Patented: US Patent US 11,885,175 B2
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 96" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Size: Sizes: 84" and 96"
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive gap at meeting edge of pairs of doors, measuring up to 3/8"
Standard-1: POSITIVE PRESSURE – CERTIFIED by UL to ANSI/10C, complies with IBC, NFPA 80 and NFPA 252 for applications to Hollow Metal and Wood fire doors rated up to 90 minute with excessive gap at meeting edge of pairs of doors, measuring up to 3/8"