NGP 5075W 36" Self-Adhesive Silicone Triple Fin Smoke Seal is designed to provide superior protection in commercial environments. Crafted from self-adhesive silicone rubber, this smoke seal exhibits excellent abrasion resistance, ensuring longevity and reliable performance. With a temperature range of -80°F to 600°F, it is engineered to withstand extreme conditions, making it suitable for various applications. This product is BHMA certified to ANSI/BHMA A156.22 performance tests, ensuring its effectiveness against heat, cold, air infiltration, and energy performance. The modified acrylic pressure-sensitive adhesive ensures easy installation and is protected by a release liner for added convenience. Measuring 1/2" wide and 3/8" tall, the NGP 5075W is available in lengths of 17', 20', 21', and 25', providing flexibility to meet specific project needs. It is resistant to aging, weathering, UV radiation, water, and various chemicals, making it a durable choice for any setting. Additionally, this smoke seal complies with multiple fire safety standards, including UL certifications for both positive pressure and acoustical performance. Choose the NGP 5075W for an effective solution that enhances both safety and efficiency in your commercial restroom partitions.
36" Self-Adhesive Silicone Triple Fin Smoke Seal
BHMA: Bhma Certified to Ansi/Bhma A156.22 Performance Tests for Heat, Cold, Air Infiltration and Energy Performance
Dimensions: 1/2" Wide x 3/8" Tall
Length: 36.0"
Resistance: Resistant to Aging, Weathering, UV Radiation, Water, Detergent, Alcohol and the Influence of Chemicals
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-4: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.