NGP 9125A (SET) 60" Anodized Aluminum Astragal with High Temperature Silicone Plus Seal offers a robust solution for maintaining the integrity of fire-rated doors. Constructed from high-quality aluminum alloy 6063 with T5 temper, this astragal is designed to withstand extreme temperature ranges from -100°F to 500°F while remaining flexible and effective in a variety of conditions. The innovative synthetic rubber polymer, Siloxane closed cell sponge, provides superior resistance against air infiltration, moisture, ozone, UV, and aging, ensuring long-lasting performance. Its flame-resistant properties make it suitable for areas utilizing FM200 or Halon fire suppression systems. This product is BHMA Certified to ANSI/BHMA A156.22, meeting rigorous performance tests for both heat and cold. Installation is straightforward, as the package includes #6 x 3/4" stainless steel sheet metal screws, and the screw holes are slotted for easy adjustment. The sleek anodized aluminum finish and black silicone seal not only enhance durability but also ensure a polished appearance. For compliance with building codes, the NGP 9125A meets IBC, NFPA 80, NFPA 105, and NFPA 252 standards, providing peace of mind for building professionals and homeowners alike.
Attributes
Application: Excellent flexibility and memory
BHMA: BHMA Certified to ANSI/BHMA A156.22 performance tests for heat and cold
Color: Silicone is black
Fasteners: #6 x 3/4" stainless steel sheet metal screws furnished
Finish: Anodized aluminum
Fire Rated: IBC, NFPA 80, NFPA105, and NFPA 252 require the gap at the meeting edge between fire labeled doors must not exceed 1/8"
Length: 60.0"
Material: Synthetic rubber polymer: Siloxane closed cell sponge
Moisture Resistant: YES
Resistance: Excellent resistance to ozone, UV and aging
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-4: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: Temperature range -100°F to 500°F, remains flexible at extreme temperatures