Net 30 terms available
NGP 320VA 36" Clear Anodized Aluminum Automatic Door Bottom for Hollow Metal Doors combines durability and functionality, making it an ideal choice for commercial restroom environments. Crafted from Aluminum Alloy 6063 with a T5 temper, this automatic door bottom is designed to withstand rigorous use, certified for up to 1,000,000 cycles under BHMA A156.22 standards. This door bottom features a flame-resistant and moisture-resistant Thermo-Plastic Vulcanizate (TPV) seal, ensuring optimal performance in various conditions, from -40°F to 250°F. It fits conveniently in a 1-5/8" x 3/4" channel, with the option of using a "furring strip" for deeper channels. The unit is furnished 1/2" shorter than the ordered length, making installation straightforward and hassle-free. With a maximum drop of 5/8", the NGP 320VA effectively minimizes air infiltration and enhances climate control, contributing to energy efficiency in your building. Available in lengths ranging from 12" to 60", this product is versatile for various door sizes. For ease of installation, #6 x 1/2" Tek screws are included. Choose NGP for reliable and effective restroom partition hardware that meets rigorous safety and performance standards.
Clear Anodized Aluminum Automatic Door Bottom for Hollow Metal Doors
BHMA: BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat and Cold
Color: Vinyl is Black
Fire Rated: Fire Ratings Apply to Metal Doors Only
Length: 36"
Material: Thermo-Plastic Vulcanizate (TPV)
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-4: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.