Sargent 12-55-70-8876F-ETL-32D RHR 12/24V Fire Rated 8800 Series Rim Exit Device, Electric Storeroom Trim, Grade 1Sargent 12-55-70-8876F-ETL-32D RHR 12/24V KIT is an advanced electric exit device designed to provide exceptional security for your building. This fire-rated, 8800 Series rim exit device features a Request to Exit (RX) function and electric storeroom exit trim, ensuring reliable performance in critical situations. It operates on auto-sensing dual voltage of 12/24VDC and offers fail-safe or fail-secure field-selectable options to suit your security needs. Crafted from durable stainless steel with a satin finish (630/US32D), this exit device meets ANSI/BHMA Grade 1 standards for cycle and strength, guaranteeing longevity in high-traffic environments. Its modular design allows for easy installation across standard width stile applications on metal doors and is suitable for both single and double door configurations. The Sargent 12-55-70-8876F device is equipped with a keyed trim and rim cylinder SFIC housing, enhancing its versatility. With a 3/4" stainless steel latch bolt, it ensures a secure closure, while the quiet operation adds to user comfort. Offering various electric options, including alarm and remote latch retraction, this exit device is a reliable choice for any facility prioritizing safety and efficiency.
KIT - Fire Rated, 8800 Series Rim Exit Device, RX (Request to Exit), Electric Storeroom Exit Trim (Auto-Sensing Dual Voltage 12/24VDC, Fail Safe/Fail Secure Field Selectable), Escutcheon with L Lever, Keyed Trim, Rim Cylinder SFIC (Small Format Interchangeable Core Housing Only, Less Core), 36in, Grade 1, RHR Right Hand Reverse, 630/US32D Stainless Steel
Notice: The info below is not item specific.
The 80 series exit device is ideal for environments that require strong and durable security solutions. Made to last the lifetime of the building, this device easily exceeds ANSI/BHMA grade 1 requirements for cycle and strength and is available in rim, mortise, surface vertical and concealed vertical rod configurations. With a modular design, this device has been crafted to be maintenance-free and provide unsurpassed security for any facility. Plus, options are available for unique applications – including delayed egress, alarmed exit and electric latch retraction – making this the go-to product for your building.
Features:
- Designed for standard width stile applications on wood and metal doors
- Also available as an HC8800 or WS8800 for hurricane-resistant applications
- Single point rim latching device
- Single door & double door applications with mullions
- Quiet operation and solid security
- ANSI/BHMA A156.3 - Grade 1
- UL10C (Fire) and UL305 (Panic) Listed
Functions:
- 04: Night latch, key retracts latch #34 cylinder supplied. ANSI 03
- 06: Key unlocks trim, trim retracts latch/trim relocks when key is removed #41 cylinder supplied. ANSI 09
- 10: No outside operation (no cylinder). ANSI 01
- 10: No outside operation (no cylinder) ET control is used as pull only. ANSI 02
- 13: Key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 15: Passage only (no cylinder). ANSI 14
- 16: Key outside retracts latch; key inside unlocks/locks O/S trim, O/S #34 cylinder & I/S #44 cylinder supplied. ANSI 10
- 40: Freewheeling trim - no outside operation (no cylinder) dummy trim. ANSI 02
- 43: Freewheeling trim - key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 44: Freewheeling trim - key retracts latch, #34 cylinder supplied. ANSI 03
- 46: Freewheeling trim - Key unlocks trim, trim retracts latch/relocks when key is removed #41 cylinder supplied. ANSI 09
- 73: Electrified ET trim - fail safe power off, unlocks lever (no cylinder)
- 74: Electrified ET trim - fail secure power off, locks lever (no cylinder)
- 75: Electrified ET trim - fail safe power off, unlocks lever, key retracts latch, #34 cylinder supplied
- 76: Electrified ET trim - fail secure power off, locks lever, key retracts latch, #34 cylinder supplied
Specifications:
- Door Type: Metal doors
- Door Thickness: 1-3/4" (44mm) minimum thickness. For doors over 1-3/4" to 5" thick, specify thickness and order as 31-
- Stile: 4-1/2" (114mm) minimum stile width
- Rail sizes as determined by door width:
- E Rail for 24" to 32" door widths, no cutting required for 32" door
- F Rail for 33" to 36" door widths, no cutting required for 36" door
- J Rail for 37" to 42" door widths, no cutting required for 42" door
- G Rail for 43" to 48" door widths, no cutting required for 48" door
- Strike: 649 Standard black nylon coated
- Dogging Feature: Hex key dogging standard on non fired rated devices; specify 16- for cylinder dogging (#41 cylinder supplied)
- Electric Options:
- AL: Alarm
- PL: SARGuide photoluminescent coated
- 53: LX Latchbolt monitor
- 54: Outside lever monitoring
- 55: Request-to-exit signal - rail monitoring
- 56: ELR Remote latch retraction
- 58: Electric dogging
- 59: Electroguard – self contained delayed egress
- Mounting Fasteners: Supplied standard with wood and machine screws. Available with through-bolts and mortise (sex) nuts
- Latch Bolt: Stainless steel, 3/4" (19mm) throw
- Device Centerline from: 41" (1041 mm) for standard applications
- Center Case Dimensions: 8-3/8" (213mm) x 2-5/8" (67mm)
- Projection: Push bar neutral – 3" (76mm), push bar depressed – 2-1/8" (54mm)
Finishes:
- 03/605 - Bright brass, clear coated
- 04/606 - Satin brass, clear coated
- 09/611 - Bright bronze, clear coated
- 10/612 - Satin bronze, clear coated
- 10B/613 - Dark oxidized satin bronze, oil rubbed
- 10BE/613E - Dark oxidized satin bronze, equivalent
- 10BL/613L - Dark oxidized satin bronze clear coated
- 14/618 - Bright nickel plated, clear coated
- 15/619 - Satin nickel plated, clear coated
- 20D/624 - Dark statuary bronze lacquered
- 26/625 - Bright chrome plated
- 26D/626 - Satin chrome plated
- 32/629 - Bright stainless steel
- 32D/630 - Satin stainless steel
- BSP - Black suede powder coat
- WSP - White suede powder coat
Attributes
Alternate Codes: 12-55-70-8876F-ETL-32D RHR 12/24V, 1255708876FETL32DRHR1224V
Category: Electrified Panic Devices, Panic Devices & Exit Alarms
Cylinder Type: Construction Core, Disposable Plastic Construction, Interchangeable , Removable Core
Door Application: Panic Devices
Door Thickness: 1-3/4"
Exit Device Options: Signal Switch in Rail
Exit Device Part Type: UL Fire Label
Finish Code: 32D, 630
Finish Color: Satin Stainless Steel
Function: Fail Secure
Handing: Right Handed Reverse
Lever Design: F, L
Series: 8800
Trim Option: Exit Trim
Voltage: 24