NGP 107SDKB 60" DKB-finish Aluminum Adjustable Perimeter Seal with Silicone Seal is designed to enhance the performance and durability of commercial restroom partitions. Crafted from high-quality Aluminum Alloy 6063 with T5 Temper, this perimeter seal is not only flame-resistant but also moisture-resistant, making it ideal for various environmental conditions. The synthetic rubber polymer, Siloxane, provides excellent flexibility and memory, ensuring a reliable seal across temperatures ranging from -100°F to 500°F. This adjustable seal features adjustment screws positioned on 10" centers, allowing for easy modifications without the need to reposition the mounting location. The product is equipped with #6 x 3/4" or #6 x 1-1/2" stainless steel screws for secure installation. Finished in a sleek dark bronze, the silicone is black, offering a sophisticated look that complements any restroom design. NGP 107SDKB is BHMA certified to ANSI/BHMA A156.22 performance tests and is recommended for areas utilizing FM200 or Halon fire suppression systems. Its exceptional resistance to ozone, UV, and aging ensures longevity and reliability, making it a valuable addition to any restroom partition setup. Enhance your space with this top-tier perimeter seal that combines functionality with professional aesthetics.
Attributes
Application: Excellent Flexibility and Memory
BHMA: BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat and Cold
Color: Silicone Is Black
Fasteners: #6 x 3/4" or #6 x 1-1/2" Stainless Steel SMS Furnished
Finish: Dark Bronze Finish
Fire Rated: Recommended for Areas Using FM200 or Halon Fire Suppression Systems
Length: 60.0"
Material: Synthetic Rubber Polymer: Siloxane
Moisture Resistant: YES
Resistance: Excellent Resistance to Ozone, UV and Aging
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Standard-4: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Standard-5: ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Temperature Range: Temperature Range -100°F To 500°F, Remains Flexible at Extreme Temperatures