NGP 159MA 36" Anodized Aluminum Magnetic Seal is an outstanding choice for enhancing the efficiency and durability of your restroom partitions. Constructed from high-quality aluminum alloy 6063 in T5 temper, this magnetic seal combines strength with a sleek anodized finish, ensuring both aesthetic appeal and lasting performance. Designed with a thermoplastic polymer, specifically Polyvinyl Chloride (PVC) formulated with a bio-based plasticizer, the NGP 159MA is both economical and environmentally friendly. Its flame-resistant and moisture-resistant properties make it suitable for various commercial applications, withstanding temperature ranges from 0°F to 140°F. This magnetic seal features a magnet encased in gray vinyl, providing an effective seal to prevent air and moisture infiltration. The #6 x 3/4" stainless steel SMS fasteners come furnished, and the slotted screw holes allow for easy adjustments during installation. With a maximum length of 144 inches, the NGP 159MA meets rigorous standards, including certification by UL for fire-rated applications. It also undergoes rigorous testing for air infiltration and sound transmission loss, ensuring compliance with industry benchmarks. Upgrade your restroom partition systems with the reliability and performance of the NGP 159MA 36" Anodized Aluminum Magnetic Seal.
36" Anodized Aluminum Magnetic Seal
Color: Magnet encased in gray vinyl
Fasteners: #6 x 3/4" stainless steel SMS furnished
Finish: Anodized aluminum
Fire Rated: Flame resistant
Length: 36.0"
Material: Thermoplastic polymer: Polyvinyl Chloride (PVC) formulated with an environmentally friendly Bio-based plasticizer
Maximum Length: Maximum length 144"
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.
Temperature Range: Temperature range 0°F to 140°F