NGP 5VA 60" Anodized Aluminum Vinyl Door Shoe is an essential component for enhancing the functionality and durability of your commercial restroom partitions. Crafted from high-quality aluminum alloy 6063 with T5 temper, this door shoe combines strength and resilience. The thermoplastic polymer, made from PVC and formulated with an environmentally friendly bio-based plasticizer, ensures both moisture and flame resistance, making it ideal for demanding environments. Designed for versatility, the NGP 5VA is effective in temperature ranges from 0°F to 140°F, providing reliable performance in various conditions. The sleek black vinyl adds a modern touch, while the anodized aluminum finish contributes to its long-lasting appeal. The product includes #6 x 3/4" stainless steel sheet metal screws, making installation straightforward, with slotted screw holes for easy adjustment. Additionally, this door shoe is certified by UL for fire safety, compliant with standards for hollow metal fire doors rated up to 3 hours and wood fire doors rated up to 90 minutes. Its smoke and draft control capabilities further enhance its suitability for commercial applications. Invest in the NGP 5VA 60" Anodized Aluminum Vinyl Door Shoe for a reliable, efficient solution that meets the stringent requirements of today’s building professionals.
60" Anodized Aluminum Vinyl Door Shoe
Color: Vinyl is black
Fasteners: #6 x 3/4" stainless steel sheet metal screws furnished
Finish: Anodized aluminum
Fire Rated: Flame resistant
Length: 60.0"
Material: Thermoplastic polymer: Polyvinyl Chloride (PVC) formulated with an environmentally friendly Bio-based plasticizer
Moisture Resistant: YES
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Standard-3: SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
Temperature Range: Temperature range 0°F to 140°F