Von Duprin RX-9949L-BE-F-626-36-LHR-06-ALK Fire-Rated Alarmed Exit Device Kit with Request to Exit Switch, Satin ChromeVon Duprin RX-9949L-BE-F-626-36-LHR-06-ALK KIT is a fire-rated, alarmed exit device designed for optimal security and functionality. This concealed vertical cable exit device features a grooved case, ensuring reliable performance while maintaining an aesthetically pleasing appearance. With its Grade 1 certification per ANSI/BHMA A156.3 2014 and UL listing for fire exit hardware, this device guarantees durability and safety. This model requires a 1-1/4 inch mortise cylinder and is equipped with a Request to Exit (RX) switch, making it ideal for high-traffic areas where secure egress is critical. The device accommodates door sizes ranging from 36 inches to 96 inches and is reversible for left-hand reverse handing, providing versatility for various installation scenarios. The RX-9949L also includes a 626 satin chrome finish, enhancing its visual appeal while providing resistance against wear and tear. The deadlocking anti-friction latch bolt offers a 5/8 inch throw for added security. Designed for hollow metal doors, it features stainless steel vertical cables for strength and reliability. Perfect for panic situations, the RX-9949L-BE is an excellent choice for commercial buildings that require efficient emergency exit solutions, ensuring both safety and ease of use for occupants.
KIT - Fire-Rated, Alarmed (Requires 1-1/4in Mortise Cylinder), CVC (Concealed Vertical Cable) Grooved Exit Device, RX (Request to Exit Switch), 996L-BE-06 Passage Lever Trim, LHR Left Hand Reverse/Reversible Handing (Snap Ring Tool Required), 36in x Up to 96in, No Dogging, Grade 1, 626/US26D Satin Chrome
Notice: The info below is not item specific.
98/9949-F Concealed vertical cable devices are certified to ANSI/BHMA A156.3 2014, grade 1 and UL listed for fire exit hardware. The 9849 device has a smooth mechanism case and the 9949 device has a grooved case. The concealed vertical cable device is non-handed except when the following device options are used: SD (special dogging), or SS (signal switch).
Specifications:
- Device Functions: Device ships EO/DT/NL; field selectable; for TP, K or L remove NL drive screw from device
- Device Lengths:
- 2' 2' (610mm) Door size
- 3' 2'4' to 3' (711mm to 914 mm) Door size
- 4' 2'10" to 4' (864 mm to 1219 mm) Door size
- Device Centerline from Finished Floor: 39 5/8" (1006 mm) standard
- Center Case: 8" x 2-3/4" x 2-3/8" (203mm x 70mm x 60mm)
- Mechanism Case: 2-1⁄4" x 2-1⁄4" (57mm x 57mm)
- Projection:
- Push bar neutral – 3-13/16" (97 mm)
- Push bar depressed – 3-1/16" (78 mm)
- Latch Bolt: Deadlocking anti-friction top and bottom bolt, 5⁄8" (16mm) throw
- Door Undercut: 3/4" (19mm) maximum. (24231516 spacer block kit needed for 3⁄4" undercut)
- Top & Bottom Latch Case: 5-13/16" x 1-1/4" x 1-7/16" (147mm x 32mm x 37mm)
- Vertical Cable: 7/32" (6mm) Diameter stainless steel cables
- Fasteners & Sex Bolts (SNB): Includes screw pack for 1-3/4" (44mm) and 2-1/4" (57mm) thick metal doors. Optional 425 SNB available
- Electrical Options:
- LX: Latch bolt monitor switch. For 98/9949 devices, LX switch monitors trim input or electric dogging of EL/QEL devices. LX switch does not monitor latch bolt condition.
- RX: Request to exit
- RX2: Double request to exit
- E: Electric locking and unlocking trim
- EL: Electric latch retraction
- ESL: Emergency secure lockdown
- QEL: Quiet electric latch retraction
- SS: Signal switch
- CX: Chexit delayed exit
- ALK: Alarm exit kit
- WP-RX: Waterproof request to exit
- CON: Allegion Connect
- Mechanical Options:
- -2: Double cylinder
- -2SI: Double cylinder with security indicator
- AX: Accessible device
- GBK: Glass bead kit
- LBL: Less bottom latch
- PN: Pneumatic latch retraction
- SG: Safety glow
- SNB: Sex bolts
- SEC: Security screws
- WH: Weep holes
- Dogging Features: Hex key dogging standard
- Dogging Options:
- CD: Cylinder dogging
- CD-CX: Chexit cylinder dogging
- CDSI: Cylinder dogging with security indicator
- HDSI: Hex dogging with security indicator
- SD: Special center case dogging
- LD: Less dogging
- DI: Dogging indicator
- CI: Cylinder dogging indicator
- Strikes:
- Top – 249 – Unfinished
- Bottom – 349 – Unfinished
Standard Trim:
- EO: No outside trim. Exit only
- DT: Dummy trim. Pull when dogged (not recommended for fire device)
- NL: Night latch
- Key retractslatchbolt
- Rim and 1-1/4" mortise cylinder
- NLOP: Night latch. Key retracts latchbolt, pull required
- TP: Thumbpiece
- Key locks and unlocks
- Rim and 1-1/4" mortise cylinder
- TPBE: Thumbpiece, blank escutcheon. Blank escutcheon always operable (no cylinder, use with DT trim)
- K/L: Knob/Lever
- Key locks and unlocks
- Rim and 1-1/4" mortise cylinder
- Handed, reversible lever
- Electrified lever operation available
- KDT/LDT: Knob/lever dummy trim. Pull when dogged
- KNL/LNL: Knob/lever, night latch
- Key retracts latchbolt
- Rim and 1-1/4" mortise cylinder
- Handed, reversible lever
- KBE/LBE: Knob/lever, blank escutcheon. Always operable (no cylinder)
- TL: Turn lever
- Key locks and unlocks (use with DT trim)
- 1-1/4" mortise cylinder
- TLBE: Turn lever, blank escutcheon. Blank escutcheon always operable (no cylinder, use with DT trim)
- TLOP: Turn lever, optional pull
- HL: Hospital latch
- Key locks and unlocks
- 1-1/4" mortise cylinder
Finishes:
- 605 - Bright brass
- 606 - Satin brass
- 612 - Satin bronze
- 625 - Bright chrome
- 626/626AM - Satin chrome
- 628 - Aluminum, anodized
- 710 - Duranodic dark bronze
- 711 - Matte black/anodized
- 643e - Aged bronze
Features
- Mechanism Case: 2-1⁄4" x 2-1⁄4" (57mm x 57mm)
- GBK: Glass bead kit
- -2SI: Double cylinder with security indicator
- DI: Dogging indicator
- -2: Double cylinder
- PN: Pneumatic latch retraction
- 3' 2'4' to 3' (711mm to 914 mm) Door size
- CD-CX: Chexit cylinder dogging
- WP-RX: Waterproof request to exit
- SG: Safety glow
- E: Electric locking and unlocking trim
- SS: Signal switch
- CI: Cylinder dogging indicator
- ESL: Emergency secure lockdown
- Push bar depressed – 3-1/16" (78 mm)
- Electrical Options:
- Strikes:
- 4' 2'10" to 4' (864 mm to 1219 mm) Door size
- Dogging Features: Hex key dogging standard
- LBL: Less bottom latch
- Center Case: 8" x 2-3/4" x 2-3/8" (203mm x 70mm x 60mm)
- Fasteners & Sex Bolts (SNB): Includes screw pack for 1-3/4" (44mm) and 2-1/4" (57mm) thick metal doors. Optional 425 SNB available
- SEC: Security screws
- Device Functions: Device ships EO/DT/NL; field selectable; for TP, K or L remove NL drive screw from device
- Latch Bolt: Deadlocking anti-friction top and bottom bolt, 5⁄8" (16mm) throw
- Projection:
- RX: Request to exit
- LD: Less dogging
- ALK: Alarm exit kit
- AX: Accessible device
- Push bar neutral – 3-13/16" (97 mm)
- 2' 2' (610mm) Door size
- EL: Electric latch retraction
- Door Undercut: 3/4" (19mm) maximum. (24231516 spacer block kit needed for 3⁄4" undercut)
- SNB: Sex bolts
- CON: Allegion Connect
- LX: Latch bolt monitor switch. For 98/9949 devices, LX switch monitors trim input or electric dogging of EL/QEL devices. LX switch does not monitor latch bolt condition.
- QEL: Quiet electric latch retraction
- Mechanical Options:
- Top – 249 – Unfinished
- Device Lengths:
- CDSI: Cylinder dogging with security indicator
- Device Centerline from Finished Floor: 39 5/8" (1006 mm) standard
- CX: Chexit delayed exit
- Bottom – 349 – Unfinished
- Vertical Cable: 7/32" (6mm) Diameter stainless steel cables
- Dogging Options:
- HDSI: Hex dogging with security indicator
- SD: Special center case dogging
- CD: Cylinder dogging
- RX2: Double request to exit
- Top & Bottom Latch Case: 5-13/16" x 1-1/4" x 1-7/16" (147mm x 32mm x 37mm)
- WH: Weep holes
Attributes
Ship via: No UPS - Common Carrier Only
Access Type: Alarmed Exit, Request to Exit
Alternate Codes: RX-9949L-BE-F-626-36-LHR-06-ALK, RX9949LBEF62636LHR06ALK
Category: Exit Alarms, Panic Devices & Exit Alarms
Center Line: 3' 3-5/8"
Certifications: A156.3, ANSI, ANSI/UL 10C, ANSI/UL 305, BHMA, CAN/ULC-S104
Device Width: 36"
Door And Lock Sensor: Pushbar Monitor
Door Application: Panic Devices & Exit Alarms
Door Frame Type: Hollow Metal Frame
Door Height: 82-96"
Door Thickness: 1-3/4"
Door Type: Hollow Metal
Exit Device Category: Concealed Vertical Cable Exit CVC
Finish Code: 626
Finish Color: Brushed Chrome, Satin Chrome
Fire Rated: Yes
Fire Rating: 180 min
Function: Blank Escutcheon, Lever
Grade: Grade 1
Handing: Left Handed Reverse
Lever Design: 6
Manufacturer: Von Duprin
Series: 98/99
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 84" or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.
Strike Type: Vertical Rod Top Strike