1. Home
  2. Shopping Cart
Adding Electric Latch Retraction to an Existing Exit Device: Which Command Access MLRK1 Kit Fits

The exit device on the door still works, but the opening now has to unlatch from a card reader or an automatic door operator. Replacing the device is not the only way. Command Access makes MLRK1 motorized latch retraction kits that go into the existing device, and each kit on its list is matched to particular exit devices, so start with the series of the one you have.

What a motorized latch retraction kit does

The Command Access kit pages describe the MLRK1 as a way to upgrade an existing device to motor-driven latch retraction in the field. The maker's February 2024 article on the MLRK explains how. The kit is small enough to fit completely inside the exit device, and its motor does not act on the latch alone. It operates the device mechanically through the push pad, the way a person pressing the pad would.

Working through the pad has a second effect. The device can be dogged electronically, and while it is dogged the pad stays pulled in, so anyone at the door can see the condition. According to the same article, the kit activates when power is present and returns to the latched position when power is removed, using the exit device's own internal springs.

The signal to retract comes from elsewhere in the system. The article describes two uses: an access control system, where a user presents a credential and the kit retracts the latch, and a door operator with an actuator, which together with a motorized device allows fully automated operation.

Which MLRK1 kit fits your exit device

The table gives the series as Command Access prints them on its kit pages. It covers seven kits; the maker's exit device kit list has more, for example kits listed for Sargent 80 Series, Detex Advantex and Value series, Dorma 9000 Series and Yale 6000 Series devices.

Device seriesKit and note
Von Duprin 33/35, 98/99MLRK1-VD; AX devices: MLRK1-VDAX
Von Duprin 22MLRK1-VD22, separate kit
Corbin Russwin 4/5000MLRK1-COR, REX kits listed
Yale 7000MLRK1-COR, same kit
Jackson 1275/1285/1295MLRK1-JAC12, built-in REX option
Kawneer 1686/1786MLRK1-JAC12, same kit
Falcon 1690/1790MLRK1-FAL17; kit list: Falcon 16/17
First Choice 3600/3700MLRK1-FAL17, same kit
AHT 4/5MLRK1-FAL17, same kit
Falcon 24/25MLRK1-FAL25, separate kit
Adams Rite 82/84/86/88/P88MLRK1-AR, built-in REX option
GAAB G352MLRK1-AR, same kit

Each of these seven kit pages links a cutsheet and installation instructions. Check your device against the cutsheet before you order. For an AX device, the MLRK1-VD page points to the MLRK1-VDAX, which is listed on that cutsheet.

Replacing an older solenoid kit? The kit list marks the VLP-KIT and VLP-UL-KIT solenoid latch pullback kits for Von Duprin 33/35 and 98/99 as end of life 09/2024, and the MLRK1-VD page links instructions for converting from a VLPKIT to the MLRK1-VD.

Not every Kawneer door has a 1686 or 1786; our Kawneer entrance door parts guide tells the two apart and names the other devices the Kawneer manual lists. The MLRK1-JAC12 page also lists a cut down kit, the MLRK1-JAC12-CDK. For the MLRK1-JAC12 and the MLRK1-AR, Command Access's campaign pages add two details: both kits work on rim and concealed vertical rod devices (our exit device types guide explains both), and on the MLRK1-AR the only hole to drill is the raceway.

Command Access power supply for an MLRK1 kit

The kit pages print no voltage or current. In the February 2024 article, Command Access recommends provisioning 1 amp for the MLRK and says actual consumption always stays below that. Once the device is in dogged mode, the article says, the kit is programmed to consume 1/4 of the amperage.

The type of supply matters too. A March 2024 article on power issues sets linear supplies against switching supplies. According to the article, a linear supply has large capacitors that store power so it is available for electrified hardware, while a switching supply has to gather the power. Without that reserve, it says, the motor starts to retract, runs out of energy and releases, and the result looks like a motor or adjustment fault. The same article recommends planning to use 80 percent of a supply's available power, even with a good supply.

The PS210 is one of the linear supplies Command Access makes. Its product page gives 110-120VAC input and 1.5 amps at 24VDC to one PTC fused output, with one solid-state input trigger, and names motor driven exit devices among the hardware its linear design suits. The maker's power supply list also includes the PS204/204B, PS220/220B and PS440B/480B. Size the supply and wire the system according to Command Access's instructions and your local codes.

Getting power into the door

Because the kit sits inside a device on the door, its wires have to cross from the frame to the door. All seven kit pages list power transfers among the recommended add-on products, next to power supplies. On the page for its ETH 5 energy transfer hinge, Command Access describes the hinge as a way to pass low voltage power from the hinge jamb to the lockset without exposed wires, and lists latch pullback devices among the hardware such hinges are commonly used with. The maker also offers a concealed power transfer, the CAT EPT, and door loops. For the templates and models of one maker's concealed transfers, see our Securitron EPT guide.

Request to exit switch

If the access control system needs a request to exit (REX) signal from the device, check what Command Access lists for your kit. Our electrified door hardware guide explains what REX and monitoring switches do.

  • MLRK1-JAC12 and MLRK1-AR: the campaign pages for both kits list an optional built-in request-to-exit switch. The maker's October 2023 article on the MLRK1-AR says the switch is available for all MLRK1-AR units.
  • MLRK1-COR: the kit page lists instructions for the CYREXKIT-M-ED, labeled Motor Rex, and the CYREXKIT-ED, labeled Mechanical Rex.
  • MLRK1-JAC12: the kit page also lists instructions for the PD15REXKIT-M-ED and the PD15REXKIT-ED.
  • Von Duprin 99/98/35/33: the maker's page of field installable REX kits lists instructions for a REX kit for these device series. The MLRK1-VD page itself does not list it, so confirm on the MLRK1-VD cutsheet before you plan on both in one device.

For any other kit, confirm the REX options on its cutsheet before you plan around them.

Our Command Access Technologies page lists the brand's products in our catalog.

Not sure which kit matches the device on your door? Our customer support team is available Monday - Friday, 8 AM - 4 PM Central Time, at 1-888-800-7789 or [email protected].

TOP Logo